For Press under 200 tons

 

06 Small type

06  Small type

VA

VA06VA06VA06

 

VS

VS06VS06VS06

 
MODEL Releasing flow rate(cm³/sec) Area of orifice (cm²) Pressure setting method Pressure setting range(kgf/cm²) Air supply(kgf/cm²)
Air type
VA06▢▢-5▢0 15500 0.7 Air pressure x 50 ratio 150-250 3-5
VA06▢▢-7▢0 13000 0.5 Air pressure x 70 ratio 210-350
VA06▢▢-9▢0 11500 0.4 Air pressure x 90 ratio 270-450
Spring type VS06▢▢-5▢0 15500 0.7 Spring Adjustment 150-250
VS06▢▢-7▢0 13000 0.5 210-350
VS06▢▢-9▢0 11500 0.4 270-450

Air consumption: 0.37 Nm³/min

Max noise: 83 db

 

 

08 Standard type

08  Standard type

 

VA08VA08VA08

 
MODEL Releasing flow rate(cm³/sec) Area of orifice (cm²) Pressure setting method Pressure setting range(kgf/cm²) Air supply(kgf/cm²)
Air type
VA08▢▢-5▢0 15500 0.7 Air pressure x 50 ratio 150-250 3-5
VA08▢▢-7▢0 13000 0.5 Air pressure x 70 ratio 210-350
VA08▢▢-9▢0 11500 0.4 Air pressure x 90 ratio 270-450

Air consumption: 0.27 Nm³/min

Max noise: 77 db

 

 

08 Standard type  |  10 Large Flow type

08  Standard type    10  Large Flow type

 

VS08-10-12VS08-10-12VS08-10-12

 
MODEL Releasing flow rate(cm³/sec) Area of orifice (cm²) Pressure setting method Pressure setting range(kgf/cm²) Air supply(kgf/cm²)
Spring type
VS08▢▢-5▢0 15500 0.7 Spring Adjustment 150-250 3-5
VS08▢▢-7▢0 13000 0.5 210-350
VS08▢▢-9▢0 11500 0.4 270-450
VS10▢▢-7▢0 18000 0.7 210-335
VS10▢▢-9▢0 14500 0.5 270-450

Air consumption: 0.27 Nm³/min

Max noise: 77 db

 
Include Oil Tank

Installation Dimensions

VA

VS08-10-12

VS

VS08-10-12VS08-10-12

 

 

VS08-10-12VS08-10-12

 
MODEL A B C D E d Volume
V▢▢▢-▢▢1
206 230 50 100 226 Ø11 1.2L
V▢▢▢-▢▢3
285 310 80 150 276 Ø13 4.0L
V▢▢▢-▢▢5
355 380 130 200 326 Ø13 8.0L