SPECIFICATION & PARAMETER OF PRESS
F: Press Rated Capacity(tons)
S: Stroke Length(mm)
N: Stroke Per Minute (SPM)
H: Rated Tonnage Point(mm)
D: Cylinder Diameter (cm)
n: Cylinder Number (pc)
h: Cylinder Stroke (cm)
NOTE
1.Hydraulic pressure (P) and air pressure (Pa) of overload protector, should be choose as higher as possible.
(Example : P=335 kgf/cm² or Pa=4.8 kgf/cm²)
2. Hydraulic Piping Size:
VA (VS)08-☐ ☐ ☐ - ☐ ☐ ☐
|
VA (VS)12-☐ ☐ ☐ - ☐ ☐ ☐
|
Size (I.D/O.D)
|
Work Pressure (maxi.)
|
Size (I.D/O.D)
|
Work Pressure (maxi.)
|
12/18 mm
|
400 kgf/cm²
|
14/22 mm
|
400 kgf/cm²
|
13/18 mm
|
320 kgf/cm²
|
16/12 mm
|
300 kgf/cm²
|
14/18 mm
|
250 kgf/cm²
|
18/22 mm
|
200 kgf/cm²
|
3. Inside diameter of air piping must be more than 6 mm